0.1.2-beta
Compatibility
Required content
Changes
Create: Networking 0.1.2 Beta Reliability Release Candidate 2
This update is the result of additional internal testing and focuses on kinetic correctness, Create compatibility, serial protection and capacity provenance.
Core fixes
- Removed the custom powered-Clutch override. Native Create Clutches now control their output normally, including when placed directly beside a Network Limiter.
- Increased loop confirmation time to reduce false loop detection while blocks and kinetic networks are still being placed or rebuilt.
- Normal provider outages no longer latch a Safety Breaker as a Supply Fault. The branch stops and resumes naturally with its source.
- Safety Breakers remain latched only for confirmed bypass loops or real output overloads.
- Removed automatic Safety-Breaker direction flipping during assignment.
Serial and parallel limiter handling
- Added conservative automatic recognition of a serial protection layout: provider -> standalone limiter -> Contract Anchor -> transfer limiter.
- Auto-detection only assigns a Safety Breaker when exactly one linked Contract Anchor exists downstream for several consecutive checks.
- Ambiguous layouts with multiple downstream contracts are left unchanged.
- Manual Safety Links through the Network Connector remain supported.
- A standalone limiter can forward native generator provenance through a serial chain.
- Capacity transferred through a Contract Anchor is marked non-forwardable, preventing imported SU from being exported again.
Capacity and loop correctness
- Local/native capacity is now tracked separately from imported contract capacity even across serial standalone limiters.
- Two networks with their own local generators may export simultaneously.
- Imported power alone cannot create exportable capacity.
- A closed limiter loop without real generation cannot sustain itself.
- Contract reservations remain attached to the provider side and are not duplicated by a serial Safety Breaker.
Visual fixes
- Enlarged and slightly protruded the static shaft in the inventory models for the Network Limiter, Contract Anchor and Compact Fuse.
- The item icons should now visibly show the integrated shaft.
Compatibility
- Minecraft 1.21.1
- NeoForge 21.1.x
- Create 6.0.x
Supplementary resources
| File | Type | Size | |
|---|---|---|---|
| createnetworking-0.1.2.jar | Unknown | 5.87 MiB |
Projects on Modrinth are automatically available through a Maven repository for use with JVM build tools such as Gradle. To learn more about the Modrinth Maven API, click here.
Note: When available, you should use the creator's maven repo instead as it will have transitive dependency information that the Modrinth Maven API does not. You may also end up with duplicate dependencies if you use a mix of Modrinth and non-Modrinth Maven repositories for your dependencies, because the group identifier will be different when served through the Modrinth Maven API.
Maven coordinates:
Version ID:
build.gradle:
repositories {
exclusiveContent {
forRepository {
maven {
name = "Modrinth"
url = "https://api.modrinth.com/maven"
}
}
// forRepositories(fg.repository) // Uncomment when using ForgeGradle
filter {
includeGroup "maven.modrinth"
}
}
}
// Standard Gradle dependency
dependencies {
implementation "maven.modrinth:xSnYrqnd:V4FJAYRd"
}
// Legacy Loom dependency
dependencies {
modImplementation "maven.modrinth:xSnYrqnd:V4FJAYRd"
}