Tags
Creators
Details
ALPHA-2.1-P3
Compatibility
Changes
Prerelease. The third pilot of 2.1, Realism: EXTENDED: screens on every sign, and control menus in place of editing signs. The save format is the same as 2.0 (format 6), so it's a drop-in upgrade. It includes everything in Pilot 1 and Pilot 2.
Screens
Every EZvac sign now has a floating screen in front of it: a dark, lit panel with room for more than a sign's four lines.
| Device | Its screen shows |
|---|---|
| Thermostat | Room temperature, ❄ Cooling to 70.0°F / ♨ Heating to / ● Holding, a capacity bar, the ETA and humidity, the outdoor temperature and season |
| Thermometers | The reading, feels-like, the outdoors, the weather and season |
| Dehumidifier / humidifier | The humidity, the setpoint, its state, a dehumidifier's tank |
| Sensor hub | Up to five sensors at once; with more, it pages along with the sign |
| RPM monitor | The RPM, a capacity bar, how many units are running |
| Settings panel | The profile, and how to change it |
- One size: all screens are the same size, so a wall of devices lines up.
- Lit: they're readable at night.
- The sign stays behind: clicking works as before, and players whose client can't show screens (such as Bedrock players through Geyser) still read the sign.
- Nothing is saved with the world: screens come back by themselves when their chunk loads, and removing EZvac leaves nothing floating.
- On by default:
displays.screens: falseinconfig.ymlturns them off.
Control menus
Right-click a thermostat sign (room or pool) to open its controls:
| Raise | Lower | |
|---|---|---|
| Top | Black pane: +5 | White pane: -5 |
| Middle | Green pane: +1 | Red pane: -1 |
| Bottom | Lime pane: +0.1 | Orange pane: -0.1 |
- Units: steps are in the server's
units, so °F, or °C withunits: C. - Limits: the target never goes past the allowed range, 60-85 °F for a room and 75-104 °F for a pool.
- Power: a lever switches the system on or off.
- Dehumidifiers and humidifiers get black and white panes for +5% / -5%, from the lowest to the highest of their
presets(35-60% and 30-50% by default), and a lever. - Sneak-right-click still switches a thermostat's system, or a unit, off or on without opening anything.
Changed
- EZvac signs can no longer be edited. A thermostat's target is set from its menu instead of line 3 of the sign.
- Everyone with
ezvac.usecan change thermostat targets from the menu, like dehumidifier setpoints. Editing line 3 neededezvac.admin;/hvac thermostat <id> setstill does. - (De)humidifier signs: clicking one opens its menu instead of stepping through the presets.
presetsnow sets the range the menu reaches.
Upgrading
config.yml gains displays.screens: true automatically, with a backup of the old file, so screens appear as soon as the server starts. Nothing else to do.
See Screens and control menus and the changelog.
Projects on Modrinth are automatically available through a Maven repository for use with JVM build tools such as Gradle. To learn more about the Modrinth Maven API, click here.
Note: When available, you should use the creator's maven repo instead as it will have transitive dependency information that the Modrinth Maven API does not. You may also end up with duplicate dependencies if you use a mix of Modrinth and non-Modrinth Maven repositories for your dependencies, because the group identifier will be different when served through the Modrinth Maven API.
Maven coordinates:
Version ID:
build.gradle:
repositories {
exclusiveContent {
forRepository {
maven {
name = "Modrinth"
url = "https://api.modrinth.com/maven"
}
}
// forRepositories(fg.repository) // Uncomment when using ForgeGradle
filter {
includeGroup "maven.modrinth"
}
}
}
// Standard Gradle dependency
dependencies {
implementation "maven.modrinth:dCv4gYwb:bgle2fMU"
}
// Legacy Loom dependency
dependencies {
modImplementation "maven.modrinth:dCv4gYwb:bgle2fMU"
}

